Edit Content
Click on the Edit Content button to edit/add the content.
Edit Content
Click on the Edit Content button to edit/add the content.
Product Data Product Details
Phi-F actor:

Typically 1.05 , depending on Sample mass and heat capacity

Test Cell

Spherical, available in 5 , 1 0 , or 20 ml sizes

Test Cell Material:

Glass for vent sizing applications

Glass, Titanium, Hastealloy and Stainless Steel for Screening

Sample Type:

Liquids and solids

Agitation:

Magnetic Stirrer

Pressure Vessel:

350 ml for standard vessel

450 m l for high pressure vessel

Pressure Range:

FV to 500 psi (35 bar) for standard vessel

FV to 1000 psi (70 bar) for high pressure vessel

Temperature Range:

-50°C to 700°C

Dosing:

Syringe, injection piston, or syringe pump

Available Scan Rates:

Up to 30°C/min

Product Data Product Details
Phi-F actor:

Typically 1.05 , depending on Sample mass and heat capacity

Test Cell

Spherical, available in 5 , 1 0 , or 20 ml sizes

Test Cell Material:

Glass for vent sizing applications

Glass, Titanium, Hastealloy and Stainless Steel for Screening

Sample Type:

Liquids and solids

Agitation:

Magnetic Stirrer

Pressure Vessel:

350 ml for standard vessel

450 m l for high pressure vessel

Pressure Range:

FV to 500 psi (35 bar) for standard vessel

FV to 1000 psi (70 bar) for high pressure vessel

Temperature Range:

-50°C to 700°C

Dosing:

Syringe, injection piston, or syringe pump

Available Scan Rates:

Up to 30°C/min

Products from - Consumables

Supplier Product Details
Altus Science

Certified Reference Material (CRM) provider, focusing on Total Organic Carbon

CRMs and Conductivity Standards along with consumables for all brands

Santis Analytical Ag

Complete solutions for analytical consumables

for various Instruments of various brands

Elemental CRM’s

Certified analytical standards for combustion &

Elemental analyzers from ppb to % level for

Sulphur, Nitrogen, Chlorine, Sulphur / Nitrogen Mix,

Solid standards, Carbon Standards, along with Miscellaneous chemicals

Aquamicron

Karl Fischer reagents consists of

Anolyte

Catholyte

Single solution

Titrant

Dehydrated solvents

Standard water-methanol

Check solution

Water standards (different concentration)

Cintra 1010 - Specifications

Product Data Product Details
Wavelength Range

190 – 1,100 nm

Spectral Bandpass

1.5 nm

Option 1.0 to 3.0 nm in 0.1 nm steps

Scanning Speed

60 to 3,200 nm/min

Stray Light
@220 nm (10 g/L Nal)
@340 nm (50 g/L NaNO2)

< 0.02%T

Wavelength Reproducibility

± 0.05 nm

Photometric Accuracy (NIST 930D standard filter, 0 to 0.5A)

± 0.001A

Cintra 2020 - Specifications

Product Data Product Details
Wavelength Range

190 – 1,200 nm

Spectral Bandpass

1.5 nm

Option 0.5 to 3.0 nm in 0.1 nm steps

Stray Light
@220 nm (10 g/L Nal)
@340 nm (50 g/L NaNO2)

< 0.0001%T

< 0.0009%T

Photometric Accuracy
(NIST 930D standard filter, 0 to 0.5A)

± 0.0004A

Photometric Accuracy
(NIST 930D standard filter, 0 to 1.0A)

± 0.0008A

Photometric Accuracy (NIST 930D standard filter, 0 to 0.5A)

± 0.000061A

Cintra 3030 - Specifications

Product Data Product Details
Wavelength Range

190 – 900 nm

Spectral Bandpass

0.2 nm to 5.0 nm in 0.1 nm step

Stray Light
@220 nm (10 g/L Nal)
@340 nm (50 g/L NaNO2)

< 0.00077%T

< 0.00008%T

Wavelength Reproducibility

± 0.019 nm

Photometric Accuracy
(NIST 930D standard filter, 0 to 0.5A)

± 0.0003A

Baseline Flatness
(baseline corrected across entire wavelength range)

< 0.00059A

Cintra 4040 - Specifications

Product Data Product Details
Wavelength Range

190 – 900 nm

Spectral Bandpass

0.1 nm to 2.0 nm in 0.1 nm steps

Stray Light
@220 nm (10 g/L Nal)
@340 nm (50 g/L NaNO2)

< 0.0003%T

< 0.000005%T

Wavelength Reproducibility

± 0.018 nm

Photometric Accuracy
(NIST 930D standard filter, 0 to 1.0A)

± 0.0003A

Baseline Flatness
(baseline corrected across entire wavelength range)

< 0.00055A

Barnstead™ GenPure™ Pro Water Purification System - Specifications

Product Data Product Details
Conductivity

0.055µS/cm

Description

GenPure Pro ultrapure water system with

UV-photo-oxidation and ultrafiltration membrane TOC

Bacterial Content

0.01 CFU/mL

Product Water Type

Type 1

Total Organic Carbon

1 to 5 ppb

Feed Water Monitoring

Integrated

Barnstead™ Pacific TII Water Purification System - Specifications

Product Data Product Details
Conductivity

0.1 to 1.0μS/cm

Daily Output

20 to 200 L

Feedwater Source

Tap

Flow Rate

7 L/hr 12L/hr 20L/hr at 10°C

Total Organic Carbon

<30 ppb

Operating Pressure

2 to 6 bar

Barnstead™ Smart2Pure™ Water Purification System - Specifications

Product Data Product Details
Smart2Pure 16UV/UF 30lits 60lits

All in One! The Smart2Pure™ Pro system is a compact system which converts tap water to into ASTM Type 1.

The Smart2Pure Pro UV/UF 16 LPH offers the choice of a 30 L or 60 L reservoir for customizable storage capacity

and ability to dispense both ASTM Type 1 and Type II water.

Conductivity

Type 1: 0.055μS/cm

Feedwater Source

Tap

Flow Rate

0.6 L/min.

Total Organic Carbon

1 to 5 ppb

Resistivity

Type 1: 18.2 Mohm.cm at 25°C

Automated Parallel synthesizer POLSTAT 3500 - Specifications

Product Data Product Details
Temperature range

-30°C to 150°C

Vessel sizes

0.5ml to 250ml (non jacketed)

Vessel shapes

Vials, test tubes, round bottom flasks and
process vessels

Removable inserts

Suitable to vessel sizes

Controlling & data handling

PiLab

Display

4.3″ LCD

Distributed temperature Control Unit POLSTAT 2300 - Specifications

Product Data Product Details
No. of Channel

Analog Inputs: 8
Digital Inputs: 4
Digital Outputs: 4
Analog Output: 1

Analog Input

3- Wire RTD: 4 {Module Termination (Jacket In & Out Sensor), Field termination (Mass & Spare Sensor)}
4-20mA: 3 {Field termination (Spare)}
2-10V DC: 1 {Module Termination (Control Valve Feedback)}

Digital Input

24VDC Isolated Digital (Dry Contact): 4
Field Termination: 2
Module Termination: 2

Communication

RS-485 MODBUS (RJ45 Termination with 24VDC, 500mA for HMI1003)
Ethernet TCP/IP Communication (for SCADA Integration)